METASU YFE-M2(A) / HRA
Trivalent chromium clear passivation agent for rack plating
Trivalent chromium passivation agent provides temporary corrosion protection for steel, and superior corrosion resistance for cast and forged parts.
<Characteristics>
- Passivation agent that contains trivalent chromium.
- Coating with high corrosion resistance can be obtained with a single coat.
- Has self-healing property.
- Enhances resistance to heat and corrosion.
- Conventional chromating equipment can be used.
Product Specifications
Attributes
Appearance | Dark purple strongly acidic liquid (METASU YFE-M2(A)) Transparent colloidal liquid (METASU YFE-HRA) |
---|
Bath makeup conditions
Chemicals used | Usage range |
---|---|
METASU YFE-M2(A) | 50 – 150ml/L |
METASU YFE-HRA | 0 – 20ml/L |
Usage conditions
Item | Range | Remark |
---|---|---|
Process temperature | 30 – 40°C | |
Process time | 30 – 60 seconds | |
pH | 1.8 – 2.4 | Verify pH value before usage. Use nitric acid for adjustment if the pH value falls outside of the specified range. |
Agitation | Yes | Use air agitation or pump stir to make the concentration of the processing liquid homogeneous. |
Replenish conditions
Chemicals used | Replenishment reference (standard) |
---|---|
METASU YFE-M2(A) 1 | 15ml/R |
METASU YFE-HRA | 5ml/R |
1) Adjust the pH value to fall within the specified range.
Note) Use nitric acid for the pH value if there is an increase in chromium concentration.
The pH electrode should be well maintained for accurate measurement.
Inquiry about the product
Feel free to contact us if you have any questions or matters to discuss.